Technical Specifications
23
Environmental:
Operating Temperature: 0° to 50° C (32° to 122° F)
Storage Temperature: -10° to 55° C (14° to 131° F)
Humidity: 10 % to 90 % non-condensing
Applications:
Shielded and unshielded twisted pair cable, 75 or
50 ohm coaxial cable, 10 or 10/100 BASE-T
Networks
Test Interface:
Main: Modular 8 connector for length, 10/100 link
identification, wiremap, office identifier/room
identifier, trace
Loopback: Modular 8 connector for patch cable
wiremap
Calibration:
User selectable NVP
NVP calculation based on known cable length
Minimum length: 15 meters (50 feet)
TDR Accuracy:
±4 % or ±2 feet whichever is greater. Any NVP
uncertainty is an additional error.
Length:
Maximum length: 450 meters (1500 feet)
Office Identifier: